Electrician in Zephyrhills, FL
Faulkner Electric is a family-owned electrical contractor out of Spring Hill, licensed by the State of Florida as a Certified Electrical Contractor under EC13006813. Zephyrhills is part of the east Pasco territory we cover.
Zephyrhills started out as a retirement colony. Around 1910, Captain Howard B. Jeffries, a Union veteran of the Civil War, organized the Zephyrhills Colony Company to settle aging soldiers who were living on their pensions. More than a century later the town still draws people who have finished their working lives. Many of them live in manufactured home communities, and many of them are only here for part of the year. Those two facts shape most of the electrical work on this side of the county, so they are what this page is about.
Your power does not start at your house
In a mobile or manufactured home community, the meter and the main disconnect usually sit on a pedestal or post beside the home, not on the home itself. The electrical code generally keeps the service equipment for a mobile home off the structure, close by and within sight of it. From that pedestal a feeder runs underground or under the floor to the distribution panel inside.
That feeder should be four separate insulated conductors: two hot legs, a neutral and an equipment ground. Older setups were sometimes run with three wires, or with a cable whose ground is bare, and the panel inside the home is supposed to keep the neutral and the ground on separate bars. When they get bonded together in the home panel, current that belongs on the neutral can find its way onto the frame, the ductwork and the metal skirting. A neutral connection that has worked loose at either end shows up differently: lights that get brighter in one room while they dim in another the moment a large appliance starts.
The space under a manufactured home is hard on wire. Moisture, heat and rodents all get at whatever runs through it. If the pedestal and the feeder are as old as the home, they deserve a look before anything else gets added. Our page on mobile home electrical work walks through the whole service and feeder setup.
Which side of 1976 your home was built on
Manufactured homes built on or after June 15, 1976 were built to the federal HUD Code, and each section carries a red certification label on the outside. Homes built before that date predate the standard. Those are the ones where we slow down, because many have been rewired in pieces over the decades with nobody keeping notes.
The material to know about from that era is aluminum branch wiring. The U.S. Consumer Product Safety Commission has long warned that houses and mobile homes wired with aluminum from about 1965 to 1973 carry an elevated fire risk. The trouble is not the wire inside the wall. It is the connections at outlets, switches and splices, which loosen and heat up over years of use. Warm cover plates, a faint smell of hot plastic, or an outlet that works one day and not the next are the signs to take seriously. The repair options, and what makes each one hold up, are on our aluminum wiring repair page.
Older homes also collect additions: a carport, a screen room, a utility shed, a Florida room closed in years ago. Each one got its power from somewhere, and not always from a dedicated circuit with a breaker sized for the load. When we trace a problem in an older home, the trail often ends at an addition somebody wired on a weekend.
When the house sits empty for months
Thousands of seasonal residents arrive in Zephyrhills each winter and head north when the weather warms up there. A home that is closed for the summer has its own electrical needs, and they mostly come down to what you leave running and what happens if something trips while nobody is around to notice.
Florida humidity does not take the summer off. Most owners leave the air conditioning or a dehumidifier running at a holding setting, which means those circuits have to work unattended for months. A refrigerator or freezer left on may be plugged into a GFCI-protected outlet, and one nuisance trip in July leaves a problem waiting for you in November. Turning the water heater off at the breaker before you leave is a sensible habit. So is labeling the panel clearly, so a neighbor or the park office can find the right breaker if you have to talk them through it over the phone.
Summer is also the stormy season here, and an empty house has nobody to notice a surge until long after it happened. A strike nearby can ruin the air conditioner's control board, which is the one appliance holding the humidity down while you are away. A surge protective device at the panel covers every circuit at once, including the appliances that were never plugged into a strip. That is what our whole-home surge protection service installs.
When you get back in the fall, spend ten minutes looking before you settle in. Check the panel for anything tripped, and if a breaker trips again right after you reset it, leave it off and call. Look at the outlets in rooms that stayed shut, and notice any warmth or odor. Pay attention the first time the air conditioning, the water heater and the dryer all run together, because that is when a tired feeder connection tends to show itself.
Outages, medical equipment and the generator question
A long outage is harder on some households than others. If someone in the home relies on an oxygen concentrator, a CPAP or other powered medical equipment, backup power stops being a convenience. In a town with this many retirees, that is the first thing worth asking about.
In a manufactured home community, the generator conversation starts with the community's rules. Many parks and associations limit where equipment can sit and whether a permanent standby unit is allowed at all. Where one is allowed, it gets connected through a transfer switch so the home can never push power back onto the utility line. Where it is not, a properly installed inlet and interlock lets a portable unit run the circuits that matter without a cord through a window. What it should never be is a cord plugged into the dryer outlet, which can put voltage on the very lines a crew is repairing. Our generator installation page covers both setups.
Downtown houses and the new edge of town
Not everyone here lives in a park. The streets around the old town center hold homes from the colony's early years, and the Zephyrhills Historic District was listed on the National Register of Historic Places in 2001. A house that old has usually been rewired at least in part. The question we care about is whether the service feeding it kept up with the rewiring.
On the other side of the picture, State Road 56 was extended east to US 301 in 2019, giving Zephyrhills a direct road to Wesley Chapel, and new homes have kept going up in and around the city.
Either way, adding a large load to a 100-amp service is arithmetic before it is installation. One hundred amps is also the minimum the code sets for a mobile home feeder, so plenty of homes here are working with exactly that. Before you buy equipment for an EV charger installation, a pool heater or a workshop, it is worth knowing what the service has left. If the answer is not enough, our page on electrical panel upgrades explains what changes.
Working with us
Most of Zephyrhills gets its power from Duke Energy, while some outlying parts of Pasco are served by Withlacoochee River Electric Cooperative. If you are not sure which one you have, the name is printed on the bill. Permits are a separate matter: for addresses inside city limits they go through the City of Zephyrhills building department, and for addresses outside the city they go through Pasco County, even when the mailing address says Zephyrhills.
Call 727-842-4920, Monday through Friday from 9 AM to 4 PM, with emergency service after hours. Tell us whether the home is in a park, roughly when it was built, and how many months of the year you are here. We will look at the pedestal, the feeder and the panel, and you will get what we found in writing.
Faulkner Electric. Family owned, based in Spring Hill, licensed statewide under EC13006813.
Questions we hear in Zephyrhills
Who is responsible for the electrical pedestal on my lot?
It depends on your community and your lot agreement. In many parks the pedestal and the lines feeding it belong to the park, while the feeder from the pedestal to your home and everything inside the home are yours. Check with management before any work starts, and we can show you where one side ends and the other begins.
My mobile home was built in the early 1970s. Does it have aluminum wiring?
It might. The Consumer Product Safety Commission identified homes and mobile homes wired from about 1965 to 1973 as the ones most likely to have aluminum branch wiring. The risk sits at outlets, switches and splices, so warm cover plates or outlets that come and go are worth a call. Please do not open them up to check yourself.
We spend the summer up north. What should we leave on while we are gone?
Most owners keep the air conditioning or a dehumidifier running to control humidity and turn the water heater off at the breaker. If you leave a refrigerator or freezer running, know whether it is on a GFCI outlet, because a single trip while you are away can spoil everything in it. Whole-home surge protection matters more when nobody is home to notice a strike.
Can a generator be installed at a manufactured home?
Often, yes, but your community's rules come first, since many parks limit where equipment can go and whether a permanent standby unit is allowed. Where a standby unit is not permitted, an inlet with an interlock lets a portable generator run your essential circuits safely. A generator should never be backfed through a dryer outlet.
Are you licensed and insured?
Yes. Florida State Certified Electrical Contractor, license EC13006813, and insured. The license number is on every page of this site and on every document we hand you.